Products
Lancet Blood Glucose Meter
  • Lancet Blood Glucose MeterLancet Blood Glucose Meter
  • Lancet Blood Glucose MeterLancet Blood Glucose Meter
  • Lancet Blood Glucose MeterLancet Blood Glucose Meter

Lancet Blood Glucose Meter

Model:KFB2
COCET KFB2 Lancet Blood Glucose Meter is a compact blood glucose monitoring device designed for accurate and efficient daily glucose testing. With dual-side test strip application, 180-set memory storage, date/time records, and multiple average calculation functions, the KFB2 supports convenient glucose management for home healthcare, pharmacies, and medical distribution channels.

COCET KFB2 Lancet Blood Glucose Meter is designed for daily blood glucose monitoring with electrochemical detection technology, dual-side test strip application, and convenient data review functions. Requiring only approximately 1μL of fresh capillary whole blood, the device provides glucose measurement within about 8 seconds and supports a measurement range of 1.1–33.3 mmol/L (19.8–599.4 mg/dL). 

Manufactured under ISO 13485 quality management requirements, with CE certification for European markets and FDA requirements for the US market, it is suitable for home healthcare, medical suppliers, and global distribution.

Product information COCET KFB2 Blood Glucose Monitor

Test Strip Application Design

The KFB2 Lancet Blood Glucose Meter adopts a practical strip application structure with dual-side blood sampling support. Users can apply blood samples from either side of the test strip, helping simplify the testing process during regular glucose monitoring.

The device requires approximately 1μL of fresh capillary whole blood and uses an electrochemical method to analyze glucose concentration. The controlled sample requirement and simple strip operation make it suitable for repeated daily testing.

Electrochemical Measurement Technology

The KFB2 uses electrochemical biosensor technology to measure blood glucose levels within a range of 1.1–33.3 mmol/L (19.8–599.4 mg/dL). The device supports a hematocrit range of 25%–65% and provides a resolution of 0.1 mmol/L for detailed measurement results.

With a response time of approximately 8 seconds, the meter is designed for users who need regular glucose checks at home, clinics, and healthcare facilities.

Data Review & Power Management

The KFB2 Lancet Blood Glucose Meter stores up to 180 measurement records with date and time information. Users can review previous results and check 7-, 14-, 21-, and 28-day average values for before-meal and after-meal measurements.

The device operates with a CR2032 3V battery and supports approximately 1,000 tests under normal conditions. The automatic power-off function activates after 180 seconds without operation to reduce unnecessary battery consumption.

Complete Testing Solution

The KFB2 is supplied as a complete glucose testing kit, including one blood glucose meter, one lancing device, one storage box, 25 lancets, and 25 test strips. The complete package configuration helps distributors provide a ready-to-use monitoring solution for end users.

Product Advantages

Low Blood Sample Requirement: The meter requires approximately 1μL of fresh capillary whole blood per test, reducing the sample requirement for routine glucose monitoring.

Wide Measurement Range: The device measures glucose levels from 1.1 to 33.3 mmol/L (19.8 to 599.4 mg/dL), covering common daily monitoring requirements.

Record Storage Function: The built-in memory stores up to 180 readings with date and time records, allowing users to review previous measurement data.

Multiple Average Calculations: The system provides 7-day, 14-day, 21-day, and 28-day average values for before-meal and after-meal records.

Long Battery Operation: Powered by a CR2032 battery, the device supports approximately 1,000 tests and includes an automatic shutdown function after 180 seconds of inactivity.

Product Testing

Before shipment, each COCET KFB2 Lancet Blood Glucose Meter undergoes functional and performance inspections to ensure stable operation. The testing process covers key components including electronic circuits, display performance, measurement functions, and overall assembly quality.

Testing Item Inspection Details
Measurement Performance Test Verifies glucose measurement performance and confirms that results meet product specifications within the defined testing range.
Electronic Function Test Checks circuit operation, display response, button functions, and system stability.
Test Strip Recognition Test Confirms correct strip insertion detection and normal measurement activation.
Battery Function Test Checks battery operation, power stability, and automatic shutdown performance.
Appearance Inspection Inspects housing quality, assembly consistency, and product appearance before packaging.

Quality Control Standards

COCET develops and manufactures blood glucose monitoring products according to medical device quality management requirements. The production process follows ISO 13485 quality management standards, covering material inspection, production control, functional testing, and final product inspection.

The KFB2 Lancet Blood Glucose Meter is designed to support international market requirements, including CE certification for European markets and FDA requirements for the United States market. These certifications and quality controls help distributors provide products that meet regional medical device regulations.

Comparison With Standard Glucose Meters

When selecting a blood glucose monitoring product, distributors and healthcare providers usually consider measurement method, operation process, data functions, and manufacturing standards. The following table shows the differences between COCET KFB2 and standard glucose meters.

Comparison Item COCET KFB2 Lancet Blood Glucose Meter Standard Glucose Meter
Blood Sample Volume Approx. 1μL fresh capillary whole blood Depends on different product designs
Blood Application Method Dual-side test strip application Different strip structures depending on manufacturer
Measurement Technology Electrochemical biosensor method Technology varies by supplier
Data Storage 180 records with date/time information and average calculation Storage functions vary by model
Power Management CR2032 battery with automatic shutdown after 180 seconds Different power designs depending on product type
Quality System Manufactured under ISO 13485 quality management system with CE/FDA market compliance support Certification depends on supplier qualification

Application Areas

The KFB2 Lancet Blood Glucose Meter is suitable for different glucose monitoring environments, including home healthcare, elderly care, pharmacies, outpatient management, and medical device distribution.

For distributors and healthcare suppliers, the product provides a complete monitoring solution with meter, lancing device, storage box, lancets, and test strips included. The compact design and simple operation make it suitable for both retail and professional healthcare channels.

Why Choose COCET

COCET specializes in the development and manufacturing of personal healthcare monitoring devices, including blood glucose meters and other medical monitoring products. The company integrates product design, production management, and quality inspection to provide stable supply solutions for global customers.

With ISO 13485 quality management standards, CE certification support for European markets, and FDA compliance support for the US market, COCET provides medical monitoring products designed for international distribution.

Technical Specifications

Name: Blood Glucose Monitor
Accessories: 1 blood glucose monitor, 1 lancing devices, 1 storage box, 25 lancing needle, 25 test strip
Display: 38mm×30mm LCD Display
Model: KFB2
Measurement scope: 1.1 ~ 33.3mmol/L (19.8 ~ 599.4mg/dl)
Blood sample: Blood sample volume: Approx. 1μL (microlitre)
Hct: 25% ~ 65%
Measuring mode: Electrochemical method
Blood sample type: Fresh capillary whole blood
Accuracy: Test range <5.5mmol/L (<100mg/dL), precision SD: <0.42mmol/L (<7.7mg/dL);
Test range ≥5.5mmol/L (≥100mg/dL), precision CV: <7.5%;
Resolution: 0.1mmol/L (0.1mg/dL)
Response: Approx. 8 secs
Memory Capacity: 180 sets, It can mark the detection value of blood glucose quality control solution before meal, after meal
Automatic power-off function: 180 seconds
Lancet Blood Glucose Meter Lancet Blood Glucose Meter

Frequently Asked Questions

Q1: What type of blood sample does the KFB2 use?

The KFB2 uses fresh capillary whole blood for testing. It requires approximately 1μL of blood sample and adopts an electrochemical measurement method to analyze glucose concentration.

Q2: Can the test strip be applied from different directions?

Yes. The KFB2 supports dual-side blood application, allowing users to apply the sample from either side of the test strip. This design helps simplify the testing process during daily glucose monitoring.

Q3: How many measurement records can be stored in the device?

The KFB2 can store up to 180 measurement records with date and time information. It also supports 7-day, 14-day, 21-day, and 28-day average calculations for before-meal and after-meal readings.

Q4: What battery does the KFB2 use?

The KFB2 operates with one CR2032 3V battery and supports approximately 1,000 tests under normal conditions. The device automatically powers off after 180 seconds without operation to help conserve battery life.

Q5: Is the KFB2 suitable for medical distributors?

Yes. The KFB2 is designed for global healthcare distribution channels, including medical suppliers, pharmacies, and home healthcare providers. COCET manufactures the product under ISO 13485 quality management standards and supports CE and FDA market requirements.

Global Healthcare Applications

The COCET KFB2 Lancet Blood Glucose Meter combines electrochemical measurement technology, convenient strip application, reliable data storage, and practical power management in one compact glucose monitoring solution. With ISO 13485 manufacturing standards, CE certification support for European markets, and FDA requirements support for the US market, it is suitable for distributors and healthcare companies seeking dependable blood glucose monitoring products.

Hot Tags: Lancet Blood Glucose Meter Manufacturer, Blood Glucose Meter Supplier, Glucose Meter Factory
Send Inquiry
Contact Info

Get a Tailored Quote for Your Medical Device Needs

Why Choose COCET:

✓ 40+ Years of Expertise — Trusted manufacturer since 1985.

✓ Global Compliance — ISO13485, CE, FDA, RFDA, TGA, INMETRO; approved by LIDL, Philips, Carrefour.

✓ Flexible OEM/ODM — Custom production; free samples before mass production.

✓ Proven Global Reach — Serving 140+ countries.

Complete the form below and our team will respond within 24 hours with a custom recommendation and competitive pricing.

X
We use cookies to offer you a better browsing experience, analyze site traffic and personalize content. By using this site, you agree to our use of cookies. Privacy Policy
RejectAccept